Top of Products > Solder-Aid > N2 System > Required equipment for N2 System
Required N2 generator, flowmeter, soldering station with N2 soldering iron.
NoteOne unit of HAKKO FX-780 and HAKKO FX-791 is required for one soldering iron.
Space-saving set sample
Combination of Hakko FX-951 and FX-780 : 163(W) x 280 (H) x 110(D)mm
The details such as features, performance, maintenance information and service life are as follows.
View details Close
Compressed air from compressor is separated by polymer membrane when it passes through the Hakko FX-780/FX-781. N2 gas goes to the Hakko FX-791 via tube, and other air constituents are discharged outside.
It utilizes the different permeability of each air constituent. N2 has lower permeability than oxygen or carbon dioxide.
Air Supply Pressure (MPa) |
N2 concentration (%) |
99.90 | 99.50 | 99.00 | 98.00 | 97.00 | 96.00 | 95.00 | 90.00 |
---|---|---|---|---|---|---|---|---|---|
0.3 | Amount of Generation | 0.15 | 0.37 | 0.48 | 0.66 | 0.88 | 1.10 | 1.30 | 2.60 |
0.4 | Amount of Generation | 0.24 | 0.57 | 0.77 | 1.10 | 1.40 | 1.70 | 2.00 | 4.40 |
0.5 | Amount of Generation | 0.35 | 0.75 | 1.10 | 1.50 | 1.90 | 2.20 | 2.90 | 5.90 |
0.6 | Amount of Generation | 0.48 | 0.97 | 1.30 | 1.80 | 2.40 | 3.10 | 3.50 | 7.50 |
0.7 | Amount of Generation | 0.55 | 1.20 | 1.60 | 2.20 | 3.10 | 3.70 | 4.20 | 9.20 |
Generated nitrogen l/min. at 25°C
Air Supply Pressure (MPa) |
Air Supply Pressure (%) |
99.90 | 99.50 | 99.00 | 98.00 | 97.00 | 96.00 | 95.00 | 90.00 |
---|---|---|---|---|---|---|---|---|---|
0.3 | Amount of Generation | 0.28 | 0.55 | 0.84 | 1.10 | 1.40 | 1.70 | 2.10 | 4.80 |
0.4 | Amount of Generation | 0.49 | 0.90 | 1.30 | 1.80 | 2.30 | 2.80 | 3.40 | 7.80 |
0.5 | Amount of Generation | 0.70 | 1.20 | 1.80 | 2.40 | 3.20 | 4.00 | 4.80 | 10.90 |
0.6 | Amount of Generation | 0.92 | 1.70 | 2.30 | 3.20 | 4.20 | 4.90 | 6.10 | 13.80 |
0.7 | Amount of Generation | 1.10 | 2.10 | 2.80 | 4.00 | 5.10 | 6.30 | 7.60 | 17.10 |
Generated nitrogen l/min. at 25°C
Connect the tube of compressor to the valve “AIR IN”. If connecting to the valve “N2 OUT”, N2 separation performance may decrease and nitrogen gas is not discharged from HAKKO FX-791.
*The picture on the right shows the connection sample of small-capacity type HAKKO FX-780.
Supply compressed air 0.3 to 0.7MPa to HAKKO FX-780 or FX-781. 0.5MPa is recommended.
NoteIf compressed air 0.2MPa or less is supplied, the performance may decrease and if 0.8MPa or more, HAKKO FX-780/FX-781 may be damaged.
In order to supply compressed air of 0.3 to 0.7MPa, followings are required.
Perform periodical maintenance of compressor, air dryer, air filter and water filter to keep HAKKO FX-780/FX-781 in good condition.
Check and clean compressor, air dryer, air fiilter and water filter periodically in accordance with the manufacture’s recommendations.
The life time of HAKKO FX-780/FX-781 is approx. 5 years under the condition of the 8-hours a day / 240 days a year operation, by the use in good condition with periodical maintenance.
NoteWhen the HAKKO FX-780 or HAKKO FX-781 end of life, the high polymer membrane needs to be replaced. As it costs as the same price as purchasing a new one, we would recommend purchasing instead of replacing.
The details such as features, performance, and maintenance information are as follows.
View details Close
HAKKO FX-791
Gas flow rate adjustment in 0.25L/min increments makes it easy to select the appropriate gas flow rate.
Turn the gas flow control knob to change flow rate.
Use the gas discharge valve to open or close N2 gas.
Operate the flowmeter in accordance with the usage note above.
NoteIf Gas Flow Control Knob is used to open/close the N2 gas, the unit may be broken.
It is possible to set up N2 System using your HAKKO soldering station. You can find out N2 soldering iron for your station.
View details Close
It is possible to set up N2 System using your HAKKO soldering station.
You can have N2 System purchasing a compatible N2 iron and other equipment for the HAKKO station you own.
N2 generator: | HAKKO FX-780 ; Small-capacity type (1 pc) or HAKKO FX-781 ; Large-capacity type (1 pc) |
---|---|
N2 Flowmeter: | HAKKO FX-791 (1 pc) |
Other equipments: | Regulator, Water filter, Air filter, Air dryer, Compressor |
N2 generator: | HAKKO FX-781; Large-capacityi type (1 pc) |
---|---|
N2 Flowmeter: | HAKKO FX-791 (2 pcs) |
Other equipment: | Regulator, Water filter, Air filter, Air dryer, Compressor |
In case higher concentrate and larger flowrate of N2 gas are required such as for auto-soldering, 2 units of FX-781 large-capacity type do the job for 1 soldering iron.
Soldering station | Soldering tip/Nozzle assembly | N2 soldering iron |
---|---|---|
Single iron FX-971 Double irons※ FX-972 |
Soldering tip T39 series |
FX-9702 No. FX9702-81 No. FX9702-811 *Tip and nozzle assembly are optional parts. |
Nozzle assembly |
||
Single iron FX-971 Double irons※ FX-972 |
Soldering tip T50 series |
FX-9704 No. FX9704-81 No. FX9704-811 *Tip and nozzle assembly are optional parts. |
Nozzle assembly |
||
Double irons※ FX-972 |
Soldering tip T53 series |
FX-9708 No. FX9708-81 No. FX9708-811 *Tip and nozzle assembly are optional parts. |
Nozzle assembly |
||
Single iron FX-888DX FX-888D FX-888(Discontinued) FR-701 Double irons※ FX-889 FR-702 |
Soldering tip T18 series |
FX-8802 No.FX8802-01 (For North America FX8802-02) *Included standard tip (T18-B) and the applicable nozzle assembly A (B3662). Other tip shapes are available as optional parts. |
Nozzle assembly |
||
Single iron FX-838 |
Soldering tip T20 series |
FX-8302 No.FX8302-01 *Tip and nozzle assembly are optional parts. |
Nozzle assembly |
||
Single iron FN-1010 |
Soldering tip T36 series |
FN-1102 No.FN1102-81 *Tip and nozzle assembly are optional parts. |
Nozzle assembly |
||
Single iron FX-805 |
Soldering tip T37 series |
FX-8005 No.FX8005-81 No.FX8005-82 *Tip and nozzle assembly are optional parts. |
Nozzle assembly |
||
Single iron FX-801(Discontinued) |
Soldering tip T33 series: Regular Type T33 series: Slim Type |
FX-8003 No.FX8003-81 *Tip and nozzle assembly are optional parts. |
Nozzle assembly |
||
Single iron FX-950 FX-951 FM-204 FM-205 Double irons※ FX-952 FM-203 Triple irons※ FM-206 |
Soldering tip T13 series for Asia, Oceania and others T17 series for North America and Europe |
FM-2026 No.FM2026-03 No.FM2026-04 (for Asia, Oceania and others) No.FM2026-06 (for North America and Europe) *Tip and nozzle assembly are optional parts. In case FX-950 is used with sleep function,please purchase FM2026-04 or FM2026-06 which are supplied with iron holder. |
Nozzle assembly |
||
Triple irons※ FM-206 |
Soldering tip T22 series |
FM-2031 No.FM2031-01 No.FM2031-02 (for North America and Europe) No.FM2031-04 (for Asia, Oceania and others) *Tip and nozzle assembly are optional parts. |
Nozzle assembly |
||
Single iron FX-951 Double irons※ FM-203 Triple irons※ FM-206 |
Soldering tip T30 series |
FM-2032 No.FM2032-51 No.FM2032-52 *Tip and nozzle assembly are optional parts. |
Nozzle assembly |
||
Hose assembly |
||
Single iron HAKKO 938 (Discontinued) |
Soldering tip T14 series (Discontinued) |
HAKKO 957 (Discontinued) No.957-01 *Tip and nozzle assembly are optional parts. |
Nozzle assembly |
||
Single iron HAKKO 936 (Discontinued) HAKKO 937 (Discontinued) HAKKO 701 (Discontinued) Double irons※ HAKKO 928 (Discontinued) |
Soldering tip T4 series |
HAKKO 953 (Discontinued) No.953-01 *Included standard tip (T4-B) and the applicable nozzle assembly A (B2670). |
Nozzle assembly |
HAKKO soldering station comes with a normal soldering iron. So, N2 iron should be purchased separately.
Generica names and required specifications are as follows.
View details Close
Required equipment | Specifications | Usage | |
---|---|---|---|
Compressor | 0.3MPa or more air pressure and 10L/min or more flow rate | Compressing air | |
Air dryer | Drying water in compressor, which is generated when compressing air. | ||
Air filter* (*Filter names varies depending on manufacturers.) |
0.3μm | Removing dust | |
Water filter* (*Filter names varies depending on manufacturers) |
0.01µm | Removing water and oil | |
Regulator | 0.3 to 0.7MPa adjustable (0.5MPa is recommended to use with HAKKO's N2 generator & flowmeter) | Adjusting compressed air | |
Air joint | OD φ0.6mm | Connecting regulator to air tube | |
Air tube | OD φ0.6mm | Supplying air from regulator to flowmeter |
NoteN2 System requires all the equipments above.