TOP > Product Information > Products > Rework / Desoldering > HAKKO 475
Products Search
What's lead-free?? What's lead-free?
What's ESD-SAFE? What's ESD-SAFE?
What's European RoHS? What's European RoHS?
Rework / Desoldering
 HAKKO 475

 Desoldering Station (External air compressor type) HAKKO 475
Available in:
Japan North America EU
Oceania Asia Other Countries
 
External Air Compressor Type Desoldering Tool

Lead-free compliant ESD-SAFE model European RoHS compliant

  HAKKO 815/816 Replacement Nozzle List
  HAKKO 809 Replacement Nozzle List

* HAKKO 474 (Vacuum pump type) is also available.

Maintenance of desoldering tool  Maintenance of desoldering tool

Features

External air compressor type desoldering tool
Built-in insulated transformer (24 V output)
Grounded nozzle
Temperature control via zero-cross switching
ESD-safe products
Use connect with the air compressor

Connectable desoldering tools (HAKKO 816/815/809)
HAKKKO 816/815
Lead-free support: Reduces clogging from solder.
The new nozzle supports devices with fine pitches.
Can also be used in HAKKO 474/701
Easy filter replacement The angle of the handle can be adjusted
(30 degrees to right and left).
Desoldering Tool HAKKO 815 and 816 / How to remove the filter pipe Desoldering Tool HAKKO 815 and 816 / The angle of the handle can be adjusted according as operation.

HAKKO 809
Can also be used in HAKKO 474/701
Easy filter replacement and others
Equipped with color indicators to determine when to clean this desoldering tool
Desoldering Tool HAKKO 809 / How to remove the filter pipe
Packing List

475: External air compressor type

Station Desoldering tool Iron Holder Other Parts
HAKKO 475 HAKKO 816 Gun type
(with S-type
Φ1.0 mm nozzle
(No.A1499))
Desoldering Tool HAKKO 816
No.635-01 (with cleaning sponge)
Iron holder No.635 for desoldering Tool HAKKO 815 and 816
475 station 1
Filter pipe 1
Cleaning pin
(for Φ1.0 mm nozzle)
1
Cleaning pin
(for heating element)
1
Cleaning drill
(for Φ1.0 mm nozzle)
1
Ceramic paper filter S 2
Ceramic paper filter L 4
Spring filter 3
Silecone grease 1
Anti-seizure 1
Wrench 1
HAKKO 815 Pen type

(with S-type
Φ1.0 mm nozzle
(No.A1499))
Desoldering Tool HAKKO 815
HAKKO 809 Gun type
(with S-type
Φ1.0 mm nozzle
(No.A1003))
Desoldering Tool HAKKO 809
No.631-06 (with cleaning sponge)
Iron holder No.631 for desoldering Tool HAKKO 809
475 station 1
Filter pipe 1
Cleaning pin
(for Φ1.0 mm nozzle)
1
Cleaning pin
(for heating element)
1
Cleaning drill
(for Φ1.0 mm nozzle)
1
Ceramic paper filter S 2
Ceramic paper filter L 4
Spring filter 3
Anti-seizure 1
Wrench 1

Specifications

HAKKO 475 Station

Power Consumption 75W(No.475), 50W(No.816/815/809)
Output Voltage 24V AC
Applied Air Pressure 490kPa (5.0kgf/cm2)(71dsi)
Compressed Air Consumption 46L/min.(1.62c.f.m.)(No. 475 only)
Temperature Range 380-480°C(716-896°F)
Nozzle to Ground Potential < 2mV (Typ.1.2mV)
Nozzle to Ground Resistance < 2Ω
Vacuum Generator Ejector type
Vacuum Pressure (Max.) 93kPa(700mmHg)
Suction Flow 20L/min
( It's the value measured at the filter case inlet of the station.)
Weight 3.0kg (475 station w/o cord)
120g(HAKKO 816)
100g(HAKKO 815)
200g(HAKKO 809)
Outer Dimensions 165(W) x 135(H) x 260(D)mm*(475 station)
180(W) x 150(H)mm(HAKKO 816)
200(W) x 80(H)mm(HAKKO 815)
135(W) x 174(H)mm(HAKKO 809)
* Without cord and hose
Replacement Parts

Replacement nozzle (for HAKKO 816/815)
Part No. φA φB Shape
A1496 0.8 1.8 Nozzle shape 1 for 815/816
A1499 1.0 2.0
A1498 0.8 2.3 Nozzle shape 2 for 815/816
A1500 1.0 2.5
A1501 1.3 3.0
A1502 1.6 3.0
A1503 2.0 3.6
A1497 0.8 2.2 Nozzle shape 3 for 815/816

Replacement nozzle (for HAKKO 809)
Part No. Inner diameter Outer diameter Shape
A1002 0.8 1.8 Nozzle shape 1 for 809 (type S)
A1003 1.0 2.0
A1004 0.8 2.3 Nozzle shape 2 for 809
A1005 1.0 2.5
A1006 1.3 3.0
A1007 1.6 3.0



Option

Part No. Part Name Applicable Model
816-01 HAKKO 816 gun type desoldering tool 816
815-01 HAKKO 815 pen type desoldering tool 815
C1183 HAKKO 809 gun type desoldering tool 809
635-01 Iron holder 815/816
A1519 Cleaning sponge 635
631-06 Iron holder 809
A1042 Cleaning sponge 631
Operation

Connection Example
Connection Example of HAKKO 475
HAKKO 475 should be connected with a compressor.
Connections sample with compressor
Adjust the regulator when the trigger is pulled to pass the air. If the regulator is adjusted without the air flow or if the dimension of the tubing is not within specifications, the suction capacity decreases. Adjust the regulator so that the pressure does not exceed 882kPa when the trigger is set to OFF. A pressure higher than 882kPa may damage components in the unit.