- Home
- Support
- Maintenance / Troubleshooting / Application Examples
- If suction force has become weak...
Maintenance / Troubleshooting / Application Examples
|
HAKKO 392/394 Maintenance Method |
|||||
![]() |
|||||
|
|||||
HAKKO 394 Names of Parts & Overhaul Procedure |
|||||
Names of Parts
Overhaul procedureIf the battery is running low, the suction force will decrease.
1. Remove the bent nozzle and pad. (Refer to Photo 1.)
2. Check the hose and pad for cracks, breaks, etc.
3. Remove the battery case lid to remove the batteries and then loosen the 3 screws to open the handle. (Refer to Photo 2.)
4. Remove the joint and silicon tube from the pump. (Refer to Photo 3.)
5. Remove the filters from the silicon tube and the joint and remove dirt and dust with an air blower, etc..
|
|||||
If the suction force is not recovered even after overhauling, it can be assumed that the pump has deteriorated. In this case, it is recommended to send the unit in for repair.
| *We recommend that you should make sure that no abnormalities are found in the wrist strap before sending it in for repair. *Clearly stipulate “repair only” or “repair and calibration” when sending it in for repair. |