MAINTENANCE/TROUBLESHOOTING/APPLICATION EXAMPLES
Top of Support & Service > MAINTENANCE/TROUBLESHOOTING/APPLICATION EXAMPLES > An error code appears on the display of the FX-973
Disconnect the power plug from the outlet, and start checking and taking action.
Please contact the store of purchase or Hakko's official distributor if the error does not disappear after you take the necessary action.
| Display | Point to be checked / How to handle |
|---|---|
|
Are the handpieces connected to the channels? Are the handpieces connected to the channels?If there is a channel that the handpiece is not connected to, press and hold its channel button for 2 seconds to turn off the power. When a channel is turned off, "OFF" will be displayed. ![]() ![]() Is the handpiece plug about to be disconnected from the unit(station)? Is the handpiece plug about to be disconnected from the unit(station)?Connect the handpiece plug to the unit (station) firmly. Is an incompatible handpiece other than FX-9701, FX-9702, FX-9703, FX-9704, FX-9705, FX-9706, FX-9707, FX-9708 and FR-4103 connected? Is an incompatible handpiece other than FX-9701, FX-9702, FX-9703, FX-9704, FX-9705, FX-9706, FX-9707, FX-9708 and FR-4103 connected?After confirming the handpiece is correct, connect the handpiece plug to the unit (station) firmly. |
|
Is the soldering tip inserted into the handpiece properly until it stops at the end? Is the soldering tip inserted into the handpiece properly until it stops at the end?Is the heating element/sensor disconnected? Is the heating element/sensor disconnected?Measure the resistance between the heating element and sensor, and if the measured value is abnormal, replace the tip. 【Measurement point/Normal resistance value】 T39: 5.7 Ω ±10% (at room temperature) ![]() T50: 8.0 Ω ±10% (at room temperature) ![]() T53: 2.9 Ω ±10% (at room temperature) ![]() FR-4103: 3.9Ω±10%(at room temperature) ![]() |
|
Is the tip size suitable for the soldering object? Is the tip size suitable for the soldering object?If the tip size is too small for the soldering object, the tip temperature drops too much due to the poor thermal capacity of the tip. Click here for more information. Please contact the store of purchase or Hakko's official distributor if you get in trouble with the low temperature alarm. |
|
We are notifying you of a power supply error to the heater. We are notifying you of a power supply error to the heater.Turn on the power switch again. |
|
Do you use a Hakko genuine soldering tip? Do you use a Hakko genuine soldering tip?Use Hakko's genuine soldering tip. |
|
Has the desoldering tool reached the set temperature? Has the desoldering tool reached the set temperature?The tool is designed not to operate when the set temperature has not been reached, even if the trigger is pulled. |
|
Are there any strong noise sources in the working area of the unit? Are there any strong noise sources in the working area of the unit?Use the unit away from the possible noise source. |