Disconnect the power plug from the outlet, and start checking and taking action.
Please contact the store of purchase or Hakko's official distributor if the error does not disappear after you take the necessary action.
| Display | Point to be checked / How to handle |
|---|---|
|
Is the handpiece plug about to be disconnected from the unit(station)? Is the handpiece plug about to be disconnected from the unit(station)?Connect the handpiece plug to the unit (station) firmly. Is an incompatible handpiece other than FU-6001 and FU-6002 connected? Is an incompatible handpiece other than FU-6001 and FU-6002 connected?After confirming the handpiece is correct, connect the handpiece plug to the unit (station) firmly. |
|
Is a wrong tip other than the TX1, TX2, TX3 series, which is applicable for the HF-600, attached to the soldering iron? Is a wrong tip other than the TX1, TX2, TX3 series, which is applicable for the HF-600, attached to the soldering iron?If so, replace it with the one from the TX1, TX2, TX3 series. |
|
Is the soldering tip inserted into the handpiece properly until it stops at the end? Is the soldering tip inserted into the handpiece properly until it stops at the end?Insert the soldering tip firmly until it stops at the end. Is the heating element/sensor disconnected? Is the heating element/sensor disconnected?Measure the resistance between the heating element and sensor, and if the measured value is abnormal, replace the tip. 【Measurement point/Normal resistance value】 TX1: 4.0Ω±10%(at room temperature) TX2: 3.4Ω±10%(at room temperature) TX3: 2.0Ω±10%(at room temperature) ![]() |
|
Is the tip size suitable for the soldering object? Is the tip size suitable for the soldering object?If the tip size is too small for the soldering object, the tip temperature drops too much due to the poor thermal capacity of the tip. Click here for more information. Please contact the store of purchase or Hakko's official distributor if you get in trouble with the low temperature alarm. |
|
Do you use a Hakko genuine soldering tip? Do you use a Hakko genuine soldering tip?Use Hakko's genuine soldering tip. |
|
Heating function is abnormal. Heating function is abnormal.Turn off the power switch. Wait for the tip to cool down. Then, turn it back on. |
|
The station may be broken. The station may be broken. |