If an alphabetic error code is shown on the display while using an FX-888DX,
please confirm the following.

Disconnect the power plug from the outlet, and start checking and taking action.
Please contact the store of purchase or Hakko's official distributor if the error does not disappear after you take the necessary action.

Display Point to be checked / How to handle
S-E
Sensor error

Is the soldering iron plug about to be disconnected from the unit(station)?

Is the soldering iron plug about to be disconnected from the unit(station)?

Is the heating element disconnected?

Is the heating element disconnected?
H-E
Low temperature alarm
The error code is displayed when the tip temperature drops below the set temperature range while soldering.

e.g. Temperature setting: 350℃, Low temperature alarm setting: 50℃
It warns with an error code and sound when the sensor temperature in the tip becomes lower than 300℃.

Please also check whether no poor soldering occurs due to insufficient heat when getting an error notice.

Is the heating element disconnected?

Is the heating element disconnected?

Is the tip size suitable for the soldering object?

Is the tip size suitable for the soldering object?
HSE
Zero-cross error

The station may be broken.

The station may be broken.
 Please contact the store of purchase or Hakko's official distributor if you cannot solve the problem by trying the above.