MAINTENANCE/TROUBLESHOOTING/APPLICATION EXAMPLES
Top of Support & Service > MAINTENANCE/TROUBLESHOOTING/APPLICATION EXAMPLES > FV-310 When you see a sign of failure
The heating element deteriorates over time and gets breakage.
Confirm the resistance value of the heating element if only cold air comes out even the motor is turning.
Procedure of measuring the resistance value of the heating element.
If the measured resistance value is not within the normal range, the heating element is broken. Replace it with a new one.
Please refer to the procedure of replacing the heating element.
Procedure of replacing the heating element.
If the measured resistance value is within the normal range, the PWB or other components may have broken. And, it is necessary to be repaired.
For the repair, please contact the store of purchase or the Hakko official distributor.
Measure the value between (a) and (b) with the resistance meter (digital multimeter).
The normal values are as follows.
Make sure to set the slide switch to "0" (OFF) and unplug before taking out the heating element for safety.
The pipe and the heating element are so hot immediately after use. Make sure applying cool down enough before removing.
Refer to the information for cooling down.
How to keep using the FV-310 for a long time (Point 1. Cooling down)
You can check the video on the procedure of replacing the heating element.
Make sure to set the slide switch to "0" (OFF) and unplug the unit for safety before the work.
The pipe and the heating element are so hot immediately after use. Make sure applying cool down enough before removing.
Refer to the information for cooling down.
How to keep using the FV-310 for a long time (Point 1. Cooling down)
The heating element and the motor deteriorate over time.
If the motor does not work and the heating element cannot get hot, set the slide switch to "0" (OFF) immediately and check the resistant value at the heater terminal (b) of the heating element.
Procedure of measuring the resistance value of the heating element.
If the measured resistance value of the terminal (b) is not within the normal range, the heating element is broken.
Please refer to the procedure of replacing the heating element.
Please refer to the procedure of replacing the heating element.
Procedure of replacing the heating element.
If the measured resistance value of the heater terminal (b) is normal, motor trouble or disconnection of the power cord is suspected. And, it is necessary to be repaired.
For the repair, please contact the store of purchase or the Hakko official distributor.
Measure the value between (b) with the resistance meter (digital multimeter).
The normal values are as follows.
Make sure to set the slide switch to "0" (OFF) and unplug the unit for safety before the work.
!The pipe and the heating element are so hot immediately after use. Make sure applying cool down enough before removing.
Refer to the information for cooling down.
How to keep using the FV-310 for a long time (Point 1. Cooling down)
You can check the video on the procedure of replacing the heating element.
Make sure to set the slide switch to "0" (OFF) and unplug the unit for safety before the work.
The pipe and the heating element are so hot immediately after use. Make sure applying cool down enough before removing.
Refer to the information for cooling down.
How to keep using the FV-310 for a long time (Point 1. Cooling down)
For the repair, please contact the store of purchase or the Hakko official distributor.