- Home
- Support
- Maintenance / Troubleshooting / Application Examples
- How to use the temperature probe for the hot air rework system (No.C1541)
Maintenance / Troubleshooting / Application Examples
How to Use the Temperature Probe for Hot Air Rework System (No. C1541) ![]() | |
The Temperature Probe for Hot Air Rework System (No. C1541) is equipped with 2 types of sensors. Before measuring temperatures as follows, connect the sensor to the thermometer ( HAKKO FG-100B, HAKKO FG-100(Discontinued) and HAKKO FG-101). |
Sensor A: |
When measuring the temperature of hot air blown from the nozzle: Correcting thermal control can be made by confirming the temperature of the hot air that is actually blown. |
Applicable products: | SMD rework HAKKO FR-801, HAKKO FR-802, HAKKO FR-803B, HAKKO 850B, HAKKO 852, HAKKO FR-830, HAKKO FM-2029 |
Sensor B: | When measuring the temperature of applicable parts (workpieces): Rework can be performed without causing damage to the parts being reworked (QFP, etc.) |
* When performing similar work using multiple Hot Air Rework Systems, see the following pages.

Thermometer lineup: | HAKKO FG-100B、HAKKO FG-100(Discontinued)、HAKKO FG-101、HAKKO FG-102 |

Temperature of hot air varies by the distance between the nozzle and the workpiece, ambient environment, room temperature, etc. Operation should be performed under the actual work environment such as with air conditioner, etc.

* For digital Hot Air models such as HAKKO FR-802, HAKKO FR-803B, etc., adjust the temperature based on the offset values.
Be careful that hot air is applied to only the end section. Failure to do so may not allow correct temperature to be measured.