Products

Smoke absorber/Air purifying type

HAKKO FA-430

HAKKO FA-430イメージ

Available in:

  • Japan
  • North America
  • EU
  • Oceania
  • Asia
  • Other Countries
  • ESD SAFE
  • RoHS
  • Air-purifying fume extractor realizing powerful suction with quiet operation
  • Freestanding flexible ducts facilitate production changeovers
  • Three airflow levels are selectable according to working environments
Contact Us
Catalog
Manuals / MSDS / Engineering documents
  • Features
  • Packaging List / Specifications
  • Soldering Tip / Nozzle
  • Replacement Parts / Option
  • Maintenance

Features

Quiet operation and powerful suction.

Exhaust noise has been reduced without sacrificing suction performance by the addition of a silencer unit to the exhaust outlet to ensure smooth air outflow. A high-performance motor with 1,500 Pa of static pressure provides powerful suction and quiet operation.

  HAKKO FA-430 Previous model (HAKKO 421)
Noise level dB (A) Air volume
m3/min
Noise level dB (A) Air volume
m3/min
High 53 4.7 60* 3.2*
Medium 50 3.7
Low 44 2.8

It is best to position the duct horizontally.

*Values measured when the unit was used with a 60 Hz power supply.


HAKKO FA-430 airflow modes
Notes regarding graph:




The HAKKO FA-430 features significantly reduced noise level in medium airflow mode despite the fact that suction performance remains almost unchanged compared to the previous model. High airflow mode also provides quieter operation than the previous model.
*Suction performance values are for when two ducts are used.
*Measured values for HAKKO 421 were taken when the unit was used with a 60 Hz power supply.



Catch harmful smoke with freestanding ducts and adjustable air volume to suit your working environment

Is your smoke absorber affected by air conditioning? Are you fed up with having to re-adjust ducts after every line change? The HAKKO FA-430 fume extractor is the answer to your problems.

Airflow adjustment

Three airflow modes are available: High, Medium, and Low. Significantly improve your working environment by using an airflow volume that suits the worksite and the job.

  • Low mode: Not easily affected by the surrounding environment. For use in small, quiet locations. (For when low-noise operation is a priority.)
  • Medium mode: For normal use.
  • High mode: For use in locations that are significantly affected by the surrounding environment. (For when suction performance is a priority.)

What do you mean by "surrounding environment"?

Smoke flows in unexpected directions due to a variety of factors; not just because of the influence of air conditioning. High mode is recommended if your worksite is situated near a doorway, in a spot where people continuously pass by, near the exhaust outlet of a large machine, or in a similar location. It is possible to use low mode in laboratories and other places where these kinds of influences are limited.

Freestanding ducts

Ducts can be bent or lengthened as desired and maintain their shape after adjustment, letting you place them exactly where suction is needed. Say goodbye forever to ducts that are long, heavy, and hard-to-handle.

Length Weight
Duct for HAKKO FA-430 1.2 m 0.6 kg
Freestanding ducts



Freestanding duct

Photo above:
Bends and stretches freely for perfect placement!

Photo on left:
Lightweight and compact, the HAKKO FA-430 weighs only 7.5 kg. Built-in handles allow the fume extractor to be moved easily, facilitating line changeovers.

*HAKKO FA-430 weighs 35% less than previous models.

Diagonally mounted duct Duct mounted directly above workpiece Arrow Duct mounted directly behind workpiece

If the duct is mounted at an angle above the workpiece, it is easily affected by air conditioning

If the duct is mounted directly above, it can be difficult to see the workpiece

 

Duct is mounted on the worktable to provide excellent suction performance


Comparison with ducts of previous model



Filter replacement notification function ensures excellent trapping efficiency can be maintained at all times

No matter how sophisticated a fume extractor is, if the filter is not replaced at the correct time, it will not be able to give maximum performance. The HAKKO FA-430 detects the number of fan revolutions and notifies the operator of the appropriate time to replace the filter, guaranteeing a comfortable working environment.

  • Pre-filter
    When the pre-filter is 80% clogged or has been used for 200 hours, the orange indicator flashes on and off.
The pre-filter indicator flashes on and off
  • Main filter
    When the 10th pre-filter needs replacing, the orange and red lamps flash on and off.

The main filter indicator flashes on and off

Aerosol particle diameter range

Usage/Applications

Proper installation of the pre-filter
  • Proper installation
    Install the pre-filter inside the frame of the main filter as shown in image 1.
    Be sure to check that there are no gaps at the corners as shown in image 2.
Correct installation
  • Improper installation
    If the pre-filter is not installed properly as shown in images 3 and 4, the main filter will degrade its original performance quickly.
Incorrect installation