Product Information

N2 System

N2 system mechanism

Nitrogen gas discharge system

Nitrogen gas discharge system Number and position of holes differs according to type of N2 soldering iron.
This illustration depicts the HAKKO FM-2026.

What is the temperature of heated nitrogen gas?

Test condition:
Measure at a point 2mm from the center of tip end with ø0.1CA sensor
Tip shape
T13-D24
Temperature
300℃ and 350℃
Temperature of nitrogen gas varies depending on tip shapes. Setting sample
Setting sample
-Soldering station HAKKO FX-951
-N2 generator HAKKO FX-780:
small-capacity type
-N2 flow meter HAKKO FX-791

Setting
temperature
(ºC)

Flow rate of
nitrogen gas
(l/min.)

Temperature of
nitrogen gas
(ºC)

300





0.5

210

1.0

250

1.5

260

2.0

263

2.5

260

350



0.5

230

1.0

240

1.5

300

2.0

320

2.5

305

Please refer to above values, which vary depending on soldering condition.
Test condition:
Measure at a point 2mm from the center of tip end with ø0.1CA sensor
Tip shape
T20-D24
Temperature
300ºC and 350ºC
Temperature of nitrogen gas varies depending on tip shapes. set example
Setting sample
-Soldering station HAKKO FX-838
-N2 generator HAKKO FX-780:
small-capacity type
-N2 flow meter HAKKO FX-791

Setting temperature
(ºC)

Flow rate of
nitrogen gas
(l/min.)

Temperature of
nitrogen gas
(ºC)

300



0.5

225

1.0

235

1.5

240

2.0

175

2.5

160

350



0.5

275

1.0

300

1.5

300

2.0

225

2.5

200