Here shows how to offset, for example HAKKO FX-951.
The offset value input method varies with its product. As for the details, please confirm the method of each product by its instruction manual. In case the offset value input method is uncertain (unavailable of its instruction manual), please contact with the nearest representative. Also instruction manuals are always available on "Document Portal" for download when needed.
|
| Tip temperature |
Decreases Increases |
| Offset value input range |
-50ºC/-90ºF |
0ºC |
+50ºC/+90ºF |
| Offset indication |
-50/-90 |
000 |
050/090 |
[CASE 2] If the "tip temperature" is lower than the "set temperature":
Input a positive offset value.
|
| Offset value input method TOP |
| Set temperature: 400ºC |
|
Tip temperature: 360ºC |
 |
 |
 |
-
Measure the tip temperature and check the difference in temperature between current "tip temperature" and "set temperature".
Setting temperature - Tip temperature = Difference in temperature
Ex. 400 - 360 = +40
-
Press the "#" button to check the current offset value.
Ex. If the current offset value is -10:
-
Calculate the offset input value from the current offset value and current difference in temperature.
Offset value + Difference in temperature = Offset input value
Ex. -10 + (+40) = +30
In this case, the offset input value shows 030.
* Calculate the figures within the square depending on situation.
|

Offset value input operation method
|