| If the sucking capability is reduced, insufficient cleaning of the following 5 sections is assumed. |
| Insert a cleaning pin suitable for the nozzle diameter into the nozzle hole to clean it. |
|
 |
It is necessary to heat the nozzle before cleaning. The nozzle and other components are at high temperatures. Be sure to wear gloves and clean them carefully. |
|
|
If the cleaning pin cannot be inserted:
If the problem cannot be solved with a cleaning pin, use a cleaning drill. However, if a cleaning drill is used, the inside of the nozzle may be scraped, accelerating the deterioration.
|
| 1. |
Insert a cleaning drill suitable for the nozzle diameter while turning it clockwise.
Failure to turn the cleaning drill when inserting or forcibly inserting the drill may damage the drill.
|
| 2. |
Pull the cleaning drill out straight.
 |
It is necessary to heat the nozzle before cleaning. The nozzle and other components are at high temperatures. Be sure to wear gloves and clean them carefully. |
If it is impossible to solve the clogging failure even by using a cleaning drill, replace the nozzle with a new one.When replacing the nozzle, apply anti-seizure lubricant to the thread section. However, for HAKKO
808 and for HAKKO 809 ( handpiece of HAKKO