Maintenance Method for HAKKO 938 Soldering Iron (HAKKO 917) |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Case 1: | The tip is not heated sufficiently. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
4 possible causes are as follows: Please check from Cause 1 to Cause 4 in order. Cause 1: The power cord and/or connection plug are disconnected. The tip is not inserted completely. Please check the entry point of power cord, connection plug and tip each. Cause 2: Lost some parts of inside Handpiece, or tip being loosen. Handpiece includes a pair of screws for nipple, Washer(2) and O-ring as a following picture. If you lose any parts at the time of tip replacement etc, the tip will loosen gradually, resulting in the cause of a failure. Please check the parts again. In case you lose any parts, please order them from a distributor.
Cause 3: Blown-out heating element due to sits life/deterioration Heating element is consumable part. It will deteriorate when it is used for a long period of time. As for blown-out checking, please follow the instruction manual. (Please refer to the following manual)
Cause 4: Blown-Heating element/Blown-fuse due to twisted lead wires being connected to the tip, or PWB being broken Flux was accumulated inside the nipple so that the nipple and the tip were stuck. When you replace the tip (or loosen the nipple), the tip and nipple turn together, resulting in the lead wires being connected to the tip were twisted.
Countermeasure
In case of broken PWB, please send it for repair through a distributor. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||