HAKKO 441B cord asse'y checking procedure
[HAKKO 441B cord asse’y checking procedure]
Measure the resistance values at the following two points. If the resistance values specified below are not obtained, the cord asse’y is broken.

1. The resistance value between connector A and connector B should be ∞.
2. The resistance value between connector A and electrode plate C should be 1Ω at maximum.
HAKKO 441B cord asse’y checking procedure