| Offset value input method TOP |
| No. |
Operation method |
Display |
| 1 |
When the card is inserted, the unit is set to the temperature setting mode and the left digit position starts to flash. |
 |
| 2 |
While the left digit position is flashing, press "#" to change the temperature setting mode to the offset mode.
(The 3-digit value displayed will show the current offset value.)
|
 |
| 3 |
Press the UP " " or DOWN " " button to select "-" or "0" for the left digit position.
[!] Each time the UP " " or DOWN " " button is pressed, display alternates between "0" (+) and "-" (-).
The photo shows the case where the offset value is being changed from 010 to -25.
|
 |
| 4 |
Press "*" to make the center digit position flash.
The photo shows the case where the offset value is being changed from 010 to -25.
|
 |
| 5 |
Press the UP" " or DOWN " " button to select "0" to "5" for the center digit position.
[!] Each time the UP " " or DOWN " " button is pressed, the value changes from "0" to "5" in sequence.
The photo shows the case where the offset value is being changed from 010 to -25.
|
 |
| 6 |
Press "*" to make the right digit position flash.
The photo shows the case where the offset value is being changed from 010 to -25.
|
 |
| 7 |
Press the UP" " or DOWN " " button to select "0" to "9" for the center digit position.
[!] Each time the UP " " or DOWN " " button is pressed, the value changes from "0" to "9" in sequence.
If a value exceeding the offset value input range (-50 to 050/090 to 090) is input, the mode will return to the operation step No. 2.
The photo shows the case where the offset value is being changed from 010 to -25.
|
 |
| 8 |
When the "*" button is pressed, the mode will return to the normal operation and be automatically adjusted to the set temperature.
* When operation is completed, remove the card if necessary.
The photo shows the case where the offset value is being changed from 010 to -25.
|
 |
| 9 |
Finally confirm that the input offset value has been set correctly.
Tip thermometer
Actually measure the tip temperature using the HAKKO FG-101 Tester, etc. to make sure that the "tip temperature" is the same as the "set temperature".
[!] If the difference between "tip temperature" and "set temperature" is large, reset the offset value to "000" (initial value) and retry the offset operation.
|

HAKKO FG-101
|