TOP > Product Tips > Offset Value Input Operation Method

Offset Value Input Operation Method
 
Offset Value Input Method

Offset value input method TOP
No. Operation method Display
1 When the card is inserted, the unit is set to the temperature setting mode and the left digit position starts to flash. When the card is inserted, the unit is set to the temperature setting mode and the left digit position starts to flash.
2 While the left digit position is flashing, press "#" to change the temperature setting mode to the offset mode.
(The 3-digit value displayed will show the current offset value.)
While the left digit position is flashing, press "#" to change the temperature setting mode to the offset mode.(The 3-digit value displayed will show the current offset value.)
3 Press the UP "" or DOWN "" button to select "-" or "0" for the left digit position.
[!] Each time the UP "" or DOWN "" button is pressed, display alternates between "0" (+) and "-" (-).
The photo shows the case where the offset value is being changed from 010 to -25.
4 Press "*" to make the center digit position flash.
The photo shows the case where the offset value is being changed from 010 to -25.
5 Press the UP"" or DOWN "" button to select "0" to "5" for the center digit position.
[!] Each time the UP "" or DOWN "" button is pressed, the value changes from "0" to "5" in sequence.
The photo shows the case where the offset value is being changed from 010 to -25.
6 Press "*" to make the right digit position flash.
The photo shows the case where the offset value is being changed from 010 to -25.
7 Press the UP"" or DOWN "" button to select "0" to "9" for the center digit position.
[!] Each time the UP "" or DOWN "" button is pressed, the value changes from "0" to "9" in sequence.
If a value exceeding the offset value input range (-50 to 050/090 to 090) is input, the mode will return to the operation step No. 2.
The photo shows the case where the offset value is being changed from 010 to -25.
8 When the "*" button is pressed, the mode will return to the normal operation and be automatically adjusted to the set temperature.

* When operation is completed, remove the card if necessary.
The photo shows the case where the offset value is being changed from 010 to -25.
9 Finally confirm that the input offset value has been set correctly.

Tip thermometer

Actually measure the tip temperature using the HAKKO FG-101 Tester, etc. to make sure that the "tip temperature" is the same as the "set temperature".
[!] If the difference between "tip temperature" and "set temperature" is large, reset the offset value to "000" (initial value) and retry the offset operation.

HAKKO FG-101
PRIVACY POLICY | SITE MAP