| Tip temperature |
Decreases Increases |
| Offset value input range |
-50ºC/-90ºF |
0ºC |
+50ºC/+90ºF |
| Offset indication |
-50/-90 |
000 |
050/090 |
[CASE 1] If the "tip temperature" is higher than the "set temperature":
Input a negative offset value.
|
| Offset value input method TOP |
| Set temperature: 360ºC |
|
Tip temperature: 395ºC |
 |
 |
 |
-
Measure the tip temperature and check the difference in temperature between current "tip temperature" and "set temperature".
Setting temperature - Tip temperature = Difference in temperature
Ex. 360 - 395 = -35
-
Press the "#" button to check the current offset value.
Ex. If the current offset value is 010:
-
Calculate the offset input value from the current offset value and current difference in temperature.
Offset value + Difference in temperature = Offset input value
Ex. 010 + (-35) = -25
In this case, the offset input value shows -25.
* Calculate the figures within the square depending on situation.
|

Offset value input operation method
|