TOP > Product Tips > Offset Value Input Method

Offset Value Input Method
 

Offset value input method TOP
Case 1 If the "tip temperature" is higher than the "set temperature", input a negative offset value.
Case 2 If the "tip temperature" is lower than the "set temperature", input a positive offset value.

Tip temperature Decreases Increases
Offset value input range -50ºC/-90ºF 0ºC +50ºC/+90ºF
Offset indication -50/-90 000 050/090

[CASE 1] If the "tip temperature" is higher than the "set temperature":
Input a negative offset value.

Offset value input method TOP
Set temperature: 360ºC Tip temperature: 395ºC
  1. Measure the tip temperature and check the difference in temperature between current "tip temperature" and "set temperature".

    Setting temperature - Tip temperature = Difference in temperature
    Ex. 360 - 395 = -35

  2. Press the "#" button to check the current offset value.

    Ex. If the current offset value is 010:

  3. Calculate the offset input value from the current offset value and current difference in temperature.

    Offset value + Difference in temperature = Offset input value
    Ex. 010 + (-35) = -25
    In this case, the offset input value shows -25.

    * Calculate the figures within the square depending on situation.


Offset value input operation method