TOP > Product Tips > Maintenance of Heating Gun
Product Tips

Maintenance of Heating Gun
If a failure phenomenon occurs

Maintenance of Heating Gun
CASE1 Although the motor is rotating, only cool air comes out.
CASE2 The motor does not rotate and the heating element is not heated.
CASE3 Although no air comes out, the heating element is heated.

CASE 1.
Although the motor is rotating, only cool air comes out.

The heating element may be broken.
The heating element deteriorates gradually during use, eventually resulting in breakage. Open the housing to check the resistance value of the heating element.

*If the resistance value is “∞”, it indicates that the heating element is broken.

How to measure the resistance value of the heating element



Note

Although heating elements are sold as replacement parts, since insulation may not be sufficiently maintained depending on replacement work conditions, it is recommended to send the unit in for repair. Please return the unit to the place of purchase for repair.